Marr College
|
Contents |
[edit] Protecting historic buildings
Historic buildings form a substantial part of our architectural landscape. Often, listed status means that these ageing buildings continue to be celebrated for their significance to the local area, and appreciated for their architectural beauty – a testament to building techniques and craftsmanship of times gone by. In order to protect these unique spaces for future generations, a sensitive approach must be taken to restoration, ensuring the original architectural characteristics are preserved.
Founded in 1935, Marr College in Troon, Scotland, is one such example. Category B-listed, the secondary school is of special historic interest, both due to its architectural style and because it was created with the financial backing of local coal merchant, Charles Kerr Marr. Serving the local community for more than 80 years, an overhaul and expansion was recently required to allow for increased accommodation.
As the building has listed status, any expansion would need to be carefully considered, allowing the building to become more suited to modern demands without losing its heritage. As part of this, meeting the necessary safety requirements of today’s Building Regulations was crucial – something which could be achieved by specifying materials appropriately.
[edit] Adequate fire protection
With increased numbers of students now attending Marr College, achieving improved building circulation was a critical part of the development. This involved a change of use of two existing courtyard spaces to create large multi-use atria, made possible with the installation of an ethylene tetrafluoroethylene (ETFE) roof. Alongside creating larger and more practical spaces, ensuring effective fire protection without detracting from the courtyards’ architectural features was critical.
That is where Pyroguard came in. Working closely with steel fabrication specialists, Martec Engineering – who provided the steelwork within the courtyards, including Schueco Jansen fire-rated glazed screens – Pyroguard supplied a variety of fire-rated glass solutions to sit within the new screens.
Acting as minimal secondary glazing, these screens allow the building’s original 1930s Crittall-style metal windows to remain in the spotlight. The screens are designed to have the smallest visual impact possible while providing the required protection to the rooms beyond, adhering to EI30 and EI60 ratings as required.
[edit] The solution
To ensure a product that could meet all the fire and loading requirements was specified, Pyroguard provided expert technical guidance to cater for the project’s constraints of working within a listed building, and helping with the specialist design of additional fire-rated glazing to be incorporated in existing timber windows and doors.
Due to the ambitious nature of the project, more than 300m2 of Pyroguard toughened glass (including Pyroguard Integrity Plus T EW30/6, Pyroguard Rapide Plus EI30/EI60 and Pyroguard Protect T-EI60) was chosen for its quality and safety features. Protecting against flames, smoke and radiant heat, the selected glazing range has the advantage of providing Marr College with additional radiant heat control and greater fire protection. In tests, this glass demonstrates the ability to maintain the amount of radiant heat to below 15 kW/m2 on the unexposed face, protecting critical evaluation routes for occupants.
Keith Milne, design manager at Martec Engineering, said: “The information and guidance from the technical team at Pyroguard was invaluable on this project, particularly in regards to creating a custom detail for the fire protection within the existing timber windows and doors. We worked hand-in-hand with Pyroguard through the whole project, ensuring the correct specification and design of products would provide the safety and security that this building required.”
“A key requirement of our steel secondary glazing fire screens, was for them to fade into the background and not detract from the character of the building. This was achieved with our manufacture of high-quality steel frames with minimal sight lines and Pyroguard’s fire-rated safety glass.’
The result of this collaboration was the creation of a space which is light, airy and elegant, providing all safety protections in the event of a fire without impacting on the architectural language of the original building.
[edit] About this article
This article was written by Andy Lake, UK Projects Director, Pyroguard. It was previously published in CIAT’s AT magazine, issue 128 Winter 2018/2019 and can be accessed here.
[edit] Related articles on Designing Buildings Wiki
- Approved document B.
- Automatic fire sprinkler systems: A good practice guide.
- Fire and rescue service.
- Fire damper.
- Fire detection and alarm system.
- Fire door.
- Fire protection engineering.
- Fire resistance.
- Fire safety design.
- Fire spread.
- Fire stopping.
- Firefighting route.
- Installing fire doors and doorsets (GG 86).
- Joint fire code.
- Protected escape route.
- Protected lobby.
- Managing fire risk in commercial buildings: A guide for facilities managers.
- Managing risks in existing buildings: An overview of UK risk-based legislation for commercial and industrial premises (FB 86).
- Means of escape.
- Sprinkler.
- The role of codes, standards and approvals in delivering fire safety.
- Understanding the factors affecting flashover of a fire in modern buildings.
- Unprotected escape route.
--CIAT
Featured articles and news
We're expanding our collaborative mission by launching DB Intelligence, an exclusive market research advisory panel. Built environment professionals can now get paid to share their expertise on industry trends, products and services.
Panel members receive direct financial incentives for participating in research projects like short surveys, 1-2-1 interviews and focus groups. Register today to shape the future of the construction sector.
Planning condition discharge in England and Wales
A brief exoplanation from a building compliance expert, with further links.
Overheating guidance and tools for building designers
Guidance for dealing with element of building fabric control that have increasing importance.
Shading for housing, a design guide
From the Good Homes Alliance and British Blind and Shutter Association.
UK Standard Skills Classification (SSC)
A shared framework for describing skills needs.
Social media ban consultation comes to close
CIOB urges UK Government to consider social media’s role in careers guidance in ban debate.
The latest of eight Skills England apprenticeship units
The addition of battery manufacturing welcomed by ECA with a warning about the risks of fast-tracked apprenticeship units.
Building Control Independent Panel final report
A precis of a key report led by Dame Hackitt with full recommendations and link to the government response.
Building Safety recap April, 2026
A short and longer run-through of the month, with links to further information and sources.
CIAT May 2026 briefing.
From medieval scribes to modern word art.
ECA welcomes crackdown on late payment and push for clean energy, whilst CIOB seek fixed cladding removal timeframes.
Cyber Security in the Built Environment
Protecting projects, data, and digital assets: A CIOB Academy TIS.
Managing competence in the built environment
ITFG publishes new industry guide on how to meet the ICC principles.
The UK's campaign to reduce noise pollution: Mythbusting, articles and topic guides.